 Model Number 5watts series

Specifications : Style:Plug-in


Dim (L*W*H) =470x270x185mm
Weight=70g

Available Model:UL, EU, UK, SAA, CCC

PRODUCT HIGHLIGHT.
Complete, inexpensive, self-contained regulated power source
Super power supply, fixed frequency control circuit guarantees Stable ,long-lasting output required by any mobile Electronics, such as mobile phones ,PDA, Digital camera , CD/MP3 player , Walkie-talkie, tester machine, HUB, Modem, Scanner, Printer and much more
Extra safe design ,all with their respective safety approvals
Ultra low no-load /standby power consumption, meeting EC 2005 green power requirements.
Light ,sleek ,and compact design.
On-line LED power indicator.
High efficiency circuitry that generates little heat .
Burn-in EMI filter.
PROTECTION:
Short circuit protection.
Over voltage protection.
Over current protection.
Thermal shutdown capability.
RELIABILITY:
Burn-in : 100% full load ,40 ±5°C,4Hrs min.
Leakage Current : 0.25mA max. at 254Vac.
Withstanding Voltage :(between primary & secondary) 3000Vac 1 minute 10mA max.
MTBF : meet MIL-HDBK-217F over 50K hours, full load,25 °C

Electrical Specifications: (Absolute Maximum Rating)
Description
Symbol
Min
Typ
Max
Units
Comment


Input


Voltage
V IN
90
120/240
264
V AC
2 Wire no Protective Ground


Frequency
F LINE
47
50/60
63
Hz



No-load Input Power(230VAC)



0.3
W



Efficiency
η

75

%



Inrush Current(240Vac)
I

40

A



Environmental







Operating Temperature
T
0
/
40
o C
Free convection, Sea level


Non-operating temperature
T
-20
/
80
o C
Free convection, Sea level


Operating humidity
T
10
/
90
%RH
Non condensing


Non-operating humidity
T
10
/
90
%RH
Non condensing






Typical model list:
INPUT CONDITION
DC OUTPUT VOLTAGE
DC OUTPUT CURRENT
OUTPUT VOLTAGE PRECISION
RIPPLE & NOISES
REGULATION
MAXIMAL OUTPUT POWER

LINE
LOAD

Input Voltage: 90-264Vac Frequency:
47-63Hz
Input current: 0.15A
1
21-24V
0-0.24A
5%
150mV
±1%
±5%
5W

2
16-20V
0-0.31A
5%
150mV
±1%
±5%
5W

3
10-15V
0-0.5A
5%
100mV
±1%
±5%
5W

4
9.4-9.9V
0-0.53A
5%
100mV
±1%
±5%
5W

5
8.8-9.3V
0-0.57A
5%
80mV
±1%
±5%
5W

6
8.2-8.7V
0-0.61A
5%
80mV
±1%
±5%
5W

7
7.6-8.1V
0-0.66A
5%
70mV
±1%
±5%
5W

8
7.0-7.5V
0-0.71A
5%
70mV
±1%
±5%
5W

9
6.4-6.9V
0-0.78A
5%
60mV
±1%
±5%
5W

10
5.8-6.3V
0-0.86A
5%
60mV
±1%
±5%
5W

11
5.2-5.7V
0-0.96A
5%
60mV
±1%
±5%
5W

12
4.6-5.1V
0-1.0A
5%
50mV
±1%
±5%
5W

13
4.0-4.5V
0-1.0A
5%
50mV
±1%
±5%
4.5W

14
3.4-3.9V
0-1.0A
5%
50mV
±1%
±5%
3.9W

15
2.8-3.3V
0-1.0A
5%
50mV
±1%
±5%
3.3W

REMARK: ( ripple and noise) 1. Measurements shall be made with an oscilloscope with 20MHz bandwidth. 2. Outputs shall be bypassed at the connector with a 0.1u F ceramic disk capacitor and a 10u F electrolytic Capacitor to simulate system loading





Inquire now